What was found
DURING HFEC OPEN HOLE INSPECTION CARRIED OUT ON RT WING LOWER SKIN PANELS, OUTER WING ACCESS DOOR CUT OUT, FOUND FOUR EACH, NR 6, 9, 10 & 35 HOLES WITH CRACK INDICATION. NEW REPAIR BUSHINGS FABRICATED & INSTALLED IAW SRM 57-20-02-2R FIG 201 REPAIR 5. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.