What was found
NUMBER 1 PYLON FWD MOUNT, OTBD AFT BOLT HOLE IS CORRODED. FINAL REAMED HOLE TO DIAMETER 0.0997" IAW SRM 54-51-81 FIG 202 FOR BUSING REPAIR, NO CORROSION NOTED. HFEC HOLE IAW NTM 51-60-00, NO CRACK INDICATION OR CORROSION NOTED. CAD PLATED FWD MOUNT, OTBD AFT HOLE IAW SRM 51-21-10 PAR 3A & SRM 54-51-81 PAR 4. FABRICATED BUSHING IAW SRM 54-51-81. INSTALLED BUSHING IAW SRM 54-51-81 PAR 5 B 2 F.