What was found
BILGE AREA BS 1661, BETWEEN STRINGER 29L & 29R, FRAME HAS LIGHT SURFACE CORROSION. REMOVED CORROSION AT FRAME STATION 1661, BETWEEN STRINGER 24R & 24L IAW SRM-51-10-02. ORIGINAL MAT .063, AFTER RE-WORK MATERIAL .052, A MATERIAL LOSS OF .011, WAS OUT OF LIMITS IAW-SRM-53-00-01 FIG 101 DET II. R & R FRAME IAW SRM-51-40-02 & DWG 146N1024, CAT A MAJOR REPAIR.