What was found
MAIN DECK FLOOR SUPPORT, JUST INBD OF L1 DOOR, CORRODED AT FASTENER HOLES. REMOVED FLOOR SUPPORT, FABRICATED, LOCATED & DRILLED, TREATED & PRIMED, INSTALLED & TOP COATED IAW SRM 51-40-21 & SRM 51-75-10. FABRICATION ACCOMPLISHED ON T15 1166327.