What was found
FUSELAGE HAS 2 EACH DENTS, STATION 1612, JUST BELOW STRINGER 26L LAP JOINT. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01-1A DETAIL III. CUT OUT DAMAGED AREA, FABRICATED DOUBLER & FILLER & INSTALLED REPAIR PARTS IAW EA F-5330-T0320834 P1.