What was found
MDCC LT SIDEWALL FLOOR LEVEL TRUSS WEB, BETWEEN FRAME 38.1-39 CRACKED. R & R SUPPORT IAW SRM 51-40-21 BATCH 0002886710. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MDCC LT SIDEWALL FLOOR LEVEL TRUSS WEB, BETWEEN FRAME 38.1-39 CRACKED. R & R SUPPORT IAW SRM 51-40-21 BATCH 0002886710. MAJOR REPAIR.