What was found
ON TAKEOFF ROLL, JUST AFTER SETTING TAKEOFF POWER, ECAM FLASHED LOW OIL PRESS, THEN WENT AWAY, GEN NR 2 FAILED SHORTLY AFTER. REJECTED TAKEOFF PRIOR TO 70 KTS. DURING IDLE RUN NR 2 ENG WAS READING 16 QTS. CHECKED OIL SERVICING ON NR 2 ENG SERVICED WITH 1/2 QT, INDICATOR READS 20 QTS IAW 12-13-79. CHECKED NR 2 ENG IDG SERVICE FOUND NR 2 IDG LOW ON OIL. SERVICED IAW 12-13-24-00-02. NO FURTHER INDICATIONS OR FAULTS NOTED. ACFT OK TO CONTINUE.