What was found
BS 1165 - 1170, RBL 45.5, SEAT TRACK FOUND CHAFED. REMOVED & FOUND OUT OF LIMITS IAW SRM 53-00-52 ALLOWABLE DAMAGE 1 REV 116, MEASURED LIP DISTANCE 0.49". SEAT TRACK, BETWEEN STATION 1075 - 1180, RBL 45.5 R & R WITH NEWLY FABRICATED SEAT TRACK IAW DWG 144N5001 SHT 3 REV A. FABRICATED SEAT TRACK IAW DWG 144N5021 SHT REV A PART 1 OF EA F-5310-T0323627A. THREE EACH EXTRA FASTENER HOLES FOUND PICKED UP ON EXISTING FLOORBEAM HORIZONTAL FLANGE AT STATION 1100, 1120 & 1140 COMPLIED WITH. REPAIR CLASSIFIED AS MAJOR.