What was found
INCOMING FUSELAGE SKIN DENT, BS 467, STRINGER 19R, DENT WAS FOUND OUT OF LIMITS DUE TO PROXIMITY TO THE LAP JOINT FASTENER LOCATIONS. ACCOMPLISHED EA F-5330-T0322263 PT 1 DATED DEC 15 2015. FUSELAGE PLATES & SKINS, DENT & GOUGE REWORKED. THIS IS A CAT B REPAIR IAW FORM 8110-3 DATED DEC 15 2015, FOR APPROVAL. MAJOR REPAIR.