What was found
HYD 1 OFF, LEVEL 1 ALERT 2, 30 HOURS INTO FLIGHT AT FL 380, HYD SYS 1 INDICATING 2.8 GALS. FOUND HYD LEAK AT SYS 1 PRESS TRANSDUCER. FURTHER TROUBLESHOOTING FOUND PACKING DETERIORATED AT FITTING SIDE, REMOVED SYS 1 PRESS TRANSDUCER. R & R PACKING ON FITTING SIDE & REINSTALLED SYS 1 PRESS TRANSDUCER IAW AMM 29-12-46-2. HYD SYS 1 PRESS INDICATION CHECKED NORMAL & NO LEAK NOTED.