What was found
BS 360, R1 DOOR CUT OUT LOWER SILL WEB, FOUND ONE ELONGATED FASTENER HOLE. REPAIRED IAW DWG 141N8422 SHT 1 REV R. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 360, R1 DOOR CUT OUT LOWER SILL WEB, FOUND ONE ELONGATED FASTENER HOLE. REPAIRED IAW DWG 141N8422 SHT 1 REV R. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100.