What was found
ON DEPARTURE FL320, HYD 1 FAIL ALERT 0 HYD QTY, 0 PRESS. SERVICED NR 1 HYD SYS IAW AMM 12-13-02-3. PRESSURIZED SYS WITH AUX PUMPS & OPERATED ALL ITEMS UNDER SYS 1, VERIFIED SYS 1 PRESS & FLUID QTY HELD. RAN NR 1 ENG IAW JRH & OPERATED ALL FLIGHT CONTROLS & ITEMS UNDER SYS 1 JUST WITH EDP`S WITH SAME RESULTS, NO DROP ON FLUID QTY & HELD PRESS. VERIFIED RESERVOIR & SYS 1, CHECKED GOOD. ACCOMPLISHED A GVI AROUND ACFT, NO LEAKS FOUND. ACFT OK FOR SERVICE.