What was found
MDCC UNDER FLOOR, ONE EACH WEB, CRACKED AT FRAME 47, Y953 ~ Y1456. REPAIRED THE WEB IAW SRM 53-15-15 FIGURE 201. THE REPAIR WAS CATEGORY B & INSPECTION THRESHOLD FROM REPAIR EMBODIMENT 24000 FC & FH NOT RELEVANT. SUBSEQUENT INSPECTION AT INTERVAL OF 3000 FC & FH NOT RELEVANT. INSPECTION METHOD DETAILED VISUAL IAW SRI 53-15-15-2-001-00. MAJOR REPAIR IAW GMM 6-2-100.