What was found
RIGHT WING OTBD FLAP, OTBD FWD HINGE, WING SIDE, ACTUATOR INBD HOLE BORE CORRODED. FOUND OUT OF LIMITS IAW CMM 57-44-09. A NEW BUSHING FABRICATED & INSTALLED IAW EA 1-5750-T0323026 PART 1 STEP 1B. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100.