What was found
ON TAKEOFF ROLL, BETWEEN 60-70 KTS, GOT A LOW GREEN HYD PRESS SYS 1 & 2. FOLLOWED BY NR 6 SPOILER FAULT. REJECTED TAKEOFF, CLEARED RUNWAY, RAN QRH. ENGS RAN IAW JRH, REF AMM 29-10-00-05 MAIN HYD POWER NORMAL AT THIS TIME, NO HISTORY & ACFT OK FOR SERVICE. FINDS IAW CREW VERBAL REPORT THE ACFT RETURNED TO NORMAL OPERATION AFTER CLEARING RUNWAY & THERE ARE NO DISCREPANCIES NOW. ACTION TAKE IAW WRI MX RAN BOTH ENGS & TESTED HYD SYS, REF AMM 29-10-00-05 ALL INDICATIONS WERE NORMAL & DISCREPANCY FACTED.