What was found
MAIN DECK FRAME 58, STRINGER 12 - 14 LT, FRAME DEFORMED & CHAFED. BLEND OUT THE CHAFED AREA PER SRM51-73-10, THE REMAINING THICKNESS WITHIN THE DESIGN TOLERANCE PER DWG A53970111, REPAIRED THE DEFORMED FRAME OF MAIN DECK FR58 STG 12-14L PER SRM53-10-13 FIG 202 , THIS REPAIR IS CATEGORY B , FIRST INSPECTION AT 42500FC AFTER REPAIR EMBODIMENT , SUBSEQUENT INSPECTION IS TBD, INSPECTION METHOD IS TBD, MAJOR REPAIR IAW GMM6-2-100