What was found
MAIN DECK FLOOR PANEL SUPPORT FOUND CRACKED, AT BS 1980 - 1993, X= 58. R & R IAW SRM 51-31-01-0G, DWG AGA7551 REV G. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOOR PANEL SUPPORT FOUND CRACKED, AT BS 1980 - 1993, X= 58. R & R IAW SRM 51-31-01-0G, DWG AGA7551 REV G. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.