What was found
DURING HFEC INSPECTION ON LT NLG WW TRUNNION WEB FITTING, REPAIRED AREA AT Y=595, FOUND CRACK LENGTH APPROX 0.13 INCH. CRACKED AREA REPAIRED IAW SRM 53-10-14-2R FIG 202 REPAIR 2. INITIAL INSPECTION TO BE CARRIED OUT AT 1,500 FLIGHT CYCLES & REPETITIVE INSPECTION AT 1,500 FLIGHT CYCLES IAW SRM 53-10-14-2R TABLE 201 REQUIREMENTS. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.