What was found
RIGHT INBD TE MAIN FLAP, UPPER OTBD ACCESS PANEL, UPPER SURFACE FOUND WITH MULTIPLE DENT MARKS & MULTIPLE DELAMINATED AREA. DAMAGED AREAS REMOVED, CLEANED & DRIED USING 150 DEG F PROCESS IAW SRM 57-53-01-2R DETAIL 1 REV 116 & SRM 57-70-10-2R REV 116. REPAIR PARTS FABRICATED & SURFACE TREATED WITH BOEGEL. INSTALLED USING 250 DEG F HOT BONDING PROCESS IAW SRM 51-70-10-2R REV 116. TAP TEST INSPECTION PERFORMED IAW SRM 57-10-06-2R REV 117, NO DISBOND NOTED. BONDED SKIN PANEL ASSEMBLY, UPPER, SRM REPAIR, RSC REPAIR TRACKING. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100.