What was found
ADC FAULT 1 DURING CLIMB OUT. ADDITIONAL DISCREPANCY 22-20 7947. PITCH TRIM 2 FAULT DURING CLIMB OUT. STAB JAM ALERT. PERFORMED BITE TEST OF MTP, FAULTED AOA SENSOR 3. R & R AOA SENSOR 3 IAW AMM 22-27-39-4. PERFORMED WIRING CHECK BETWEEN AOA SENSOR 3 & D FAC 1. ALL WIRES CHECKED GOOD IAW AWM 22-22-01 & 30-31-07. PERFORMED AFS LAND TEST IAW AMM 22-40-00-5 & 22-00-00-2. OPERATIONS CHECKED GOOD AT THIS TIME. PERFORMED ADC 1 & 2 BITE TEST IAW TSM 34-10-00 TASK 3 A,B & C, NO FAULTS FOUND. AOA SENSOR 3 NEEDS TO BE SEALED. SEALED AOA NR 3 IAW 22-27-39-4. ACFT IS OK FOR SERVICE.