What was found
UPON REMOVAL OF PRODUCTION SPLICE AT STATION 1460, FOUND STRINGER 28L CRACKED, STATION 1460 - 1480. REMOVED DAMAGED SECTION OF STRINGER 28L IAW SRM 53-00-03-2R. FABRICATED REPAIR PARTS, SPLICES FROM BAC 1498-236 PO 963FB -00085, DIMS 13.1" , 13.4", SHIMS FROM 7075-T6.050 PO ST-00008673 DIMS 13.1X .825, STRINGER SECTIONS FROM PN 5317320 PO 963FB -00090 DIMS 11.2 & 15.86. INSTALLED REPAIR PARTS IAW SRM 53-00-03-2R REPAIR 2 51-40-05-0G. THIS IS A CATEGORY A REPAIR.