What was found
FLOORBEAM AT STATION 1681, HAS SEVERAL AREAS OF CORROSION ON UPPER CHORD. REMOVED CORROSION & CHECK LIMITS IS FOUND OUT OF LIMITS IAW SRM 53-00-51-1A DETAIL III. R & R FLOORBEAM IAW DWG 146N5091, PN 146N5111-4, STATION 1681 MATERIAL PN BAC 1518-827 A BATCH 0002877570 IAW SRM 51-40-02. CATEGORY A MAJOR REPAIR.