What was found
CENTER MAIN DECK UNDER FLOOR, FRAME 47, BETWEEN Y953 & Y1456, VERTICAL WEB CRACKED. REPLACED THE VERTICAL WEB, CTR MAIN DECK UNDER FLOOR IAW SRM 51-40-21. THE REPAIR WAS CATEGORY A & WAS CLASSIFIED AS MAJOR IAW GMM 6-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CENTER MAIN DECK UNDER FLOOR, FRAME 47, BETWEEN Y953 & Y1456, VERTICAL WEB CRACKED. REPLACED THE VERTICAL WEB, CTR MAIN DECK UNDER FLOOR IAW SRM 51-40-21. THE REPAIR WAS CATEGORY A & WAS CLASSIFIED AS MAJOR IAW GMM 6-2-100.