What was found
LEFT WING OTBD FLAP, INBD FWD HINGE BRACKET, WING SIDE, LOWER OTBD STUD ATTACH BORE FOUND CORROSION. CORROSION EXCEEDED LIMIT AS PER MD-11 CMM 57-44-09. EXISTING HOLE DIAMATER 0.706 INCH ; FINAL HOLE DIAMATER 0.725 INCH ; MAXIMUM ALLOWABLE DIAMATER 0.709 INCH. REPAIR BUSHING FABRICATED AND INSTALLED AS PER EA 1-5750-T0324816 PART 1. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100. REFER TO WRI: 57503810 FOR WORK DETAILS.