What was found
RIGHT WING OTBD FLAP, OTBD FWD HINGE BRACKET, WING SIDE, ATTACH UPPER BORE FOUND CORROSION. NR 7 HOLE REWORKED & FOUND EXCEEDED LIMIT IAW CMM 57-44-09. EXISTING HOLE DIAMETER 0.323 INCHES, FINAL HOLE DIAMETER 0.406 INCHES & MAXIMUM ALLOWABLE DIAMETER 0.391 INCHES. REPAIRED BUSHING, FABRICATED BY MACHINING & INSTALLED IAW EA 1-5750-T0324819 PART 1 STEP 1B. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100. REFER TO WRI 57503808 FOR WORK DETAILS.