What was found
DURING PREFLIGHT WALK AROUND FOUND NR 2 RT GND SPOILER EXTENDED. FURTHER TROUBLESHOOTING FOUND BROKEN ROD END ON SPOILER TO ACTUATOR. DURING FURTHER INSPECTION FOUND BELL CRANK HAD GOUGES WHERE ROD WAS HITTING AGAINST IT. ROD ASSEMBLY & RT LEVER ASSEMBLY REMOVED IAW MM 27-64-11-04. RELEASED FOR SERVICE IAW MEL 27-61-01-A CATEGORY C EXPIRATION 30 APR 16. AFFECTED SURFACES VERIFIED AS DEACTIVATED IN RETRACTED POSITION. SEE ERS EA 6-2760-T0324842 FOR WORK DONE. WORK DONE IAW MM 27-64-11-04. R&R THE NR 2 RT SPOILER CONTROL ROD AND DUMPER JACK LEVER AND ADJUSTED NR 2 SPOILER REF AMM 27-61-54-04, 27-64-11-04, SMP 20-21-12-00 AND DWG A276.40155. RIG AND OPS CHECKS GOOD.