What was found
DURING INSPECTION IAW WC E 9-5730-E0317303 A P2 ON RT WING LE AT CORNER 11, FOUND TWO EACH CRACKS, LENGTH APPROX 0.39. REPAIR CARRIED OUT AT RT WING LE CORNER 11 AT XOS 610.844 IAW SRM 57-40-01-2R FIG 201 REPAIR 18. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100. INITIAL INSPECTION TO BE CARRIED OUT AT NEXT C CHECK NOT EXCEEDING 24 MONTHS & REPETITIVE INSPECTION TO BE CARRIED OUT AT EVERY C CHECK NOT EXCEEDING 24 MONTHS IAW SRM 57-40-01-2R FIG 201 REPAIR 18 TABLE 204.