What was found
FLIGHT TEST FTAM 4-66, RT ENG SHUTDOWN & RE-LIGHT FL 220 AIRSPEED 300KTS. AFTER THE NORMAL SHUTDOWN OF THE RT ENG, RELIGHT WAS ATTEMPTED. WHEN THE RT FUEL CONTROL SWITCH WAS POSITIONED FROM CUT OFF TO RUN THE SPAR, VLV OPEN & THE ENG VLV ON THE RT ENG DID NOT OPEN. THE ENG VLV, WITH THE COMMANDED OPEN POSITION. THERE WERE NO FUEL FLOW INDICATION. WHEN THE RT FUEL CONTROL SWITCH WAS MOVED FROM RUN TO CUT OFF, THE ENG VLV LIGHT WENT OUT INDICATING THE ENG VLV WAS IN AGREEMENT WITH THE COMMANDED CLOSED POSITION. R & R RT ENG LP & HP FUEL PUMPS IAW AMM 73-11-03-4 & 73-11-01-4. OPERATIONS & LEAK CHECKED GOOD IAW AMM 71-00-00-5-3. REMOVED HP FUEL PUMP.