What was found
LEFT WING, OTBD FLAP VANE HORN FITTING D FWD HOLE CORROSION. CORROSION REWORKED AND FOUND EXCEEDED LIMIT IAW SRM 57-50-02-2R, FIG 201, EXISTING SIZE: LENGTH 0.858", WIDTH: 0.598", FINAL SIZE: LENGTH 0.9495", WIDTH: 0.649", MAXIMUM ALLOWABLE SIZE: LENGTH 0.940", WIDTH: 0.670". REPAIR BUSHING FABRICATED IAW EA 1-5750-T0325479, PART 1, STEP 2C, TITLE: WINGS, FLIGHT SURFACES EO1-5750-7-5002, LT WING, OTBD FLAP, VANE ASSY-TRACK SUPPORT REWORK AND REFER TO WRI: 57507896 FOR WORK DETAILS. BUSHING INSTALLED IAW AMM 27-50-32-4. FITTING REMOVED AND INSTALLED IAW AMM 27-50-32-4. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100.