What was found
LEFT WING, OTBD FLAP VANE HORN FITTING B FWD HOLE CORROSION. CORROSION REWORKED AND FOUND EXCEEDED LIMIT IAW SRM 57-50-02-2R, FIG 201, EXISTING SIZE: LENGTH 0.915", WIDTH: 0.621". FINAL SIZE: LENGTH 1.0395", WIDTH: 0.7395", MAXIMUM ALLOWABLE SIZE: LENGTH 0.940", WIDTH: 0.670". REPAIR BUSHING FABRICATED IAW EA 1-5750-T0325479, PART 1, STEP 2A. TITLE: WINGS-FLIGHT SURFACES EO1-5750-7-5002 LT WING, OTBD FLAP VANE ASSY, TRACK SUPPORT REWORK AND REFER TO WRI: 57507896 FOR WORK DETAILS, BUSHING INSTALLED IAW AMM 27-50-32-4. FITTING REMOVED AND INSTALLED IAW AMM 27-50-32-4. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100.