What was found
NUMBER 2 ENG STRUT TO DIAGONAL BRACE FITTING, HORIZONTAL OTBD AFT, INBD MOST FASTENER HOLE HAS CORROSION. WORK PERFORMED ON EA F-5450-T0325148 AT NR 2 ENG STRUT TO DIAGONAL BRACE FITTING, HORIZONTAL FLANGE OTBD AFT FASTENER HOLE. NACELLE & PYLON- PYLON STRUCTURES DEVIATION TO EO F-5450-7-5006 DUE TO CORROSION IN BULKHEAD AT BRACE FITTING MOUNT HOLE ON NR 2 RT PYLON.