What was found
AFT PIT STATION 1260, CORROSION ON FRAME UPPER FLANGE AT FLOOR STRINGER LBL 2.29. REMOVED CORROSION IAW SRM 51-10-02-0G. AFTER REWORK AREA WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A.FIG 101 DET V, ORIG MAT .063, .016 MAT LOSS. R & R FRAME IAW SRM 51-40-02-0G & DWG 146N1004, STATION 1260, STRINGER 24L - 24R. FABRICATED ON T16 1201528. MAJOR REPAIR.