What was found
MAIN DECK FRAME 14, -Y953, FLOOR SUPPORT CRACKED. REPAIRED THE SUPPORT AT MAIN DECK FRAME 11-FRAME 14, Y953 IAW SRM 53-12-15-201, FIG 207. THE REPAIR WAS CATEGORY B, THE INSPECTION THRESHOLD WAS 51000FC/89000FH AFTER REPAIR EMBODIMENT, THE SUBSEQUENT INSPECTION INTERVAL AND METHOD WERE TBD. MAJOR REPAIR IAW GMM6-2-100.