What was found
DENT, FUSELAGE EXTERIOR SKIN, APPROX STATION 508, STRINGER 29 RT. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01-1A. CUTOUT DAMAGED SKIN AT STA 508, STR 29R, DIM 1.85" X 2.45", C/W NDT AND FABRICATED, INSTALLED REPAIR DOUBLER FROM 2024-T3, .050" DIM 10.5" X 9.2" IAW SRM 53-00-01-2R, REPAIR 16. THIS IS A MAJOR REPAIR.