What was found
LEFT WING OTBD FLAP, OTBD FWD HINGE, WING SIDE, LOWER MOUNT INBD HOLE BORE CORROSION. HINGE REWORKED AND FOUND EXCEEDED LIMIT IAW CMM 57-44-09. EXISTING HOLE, DIA: 0.579" FINAL HOLE DIA: 0.598" MAXIMUM ALLOWABLE DIA: 0.584". REPAIR BUSHING FABRICATED AND INSTALLED IAW EA 1-5750-T0325889 PT1 STEP 1A. WINGS, FLT SURFACES-EO 1-5750-7-5002 , LT WING-OTBD FLAP OTBD HINGE ASSY, WING SIDE, CORROSION REPAIR. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100.