What was found
LEFT WING OTBD FLAP, OTBD FWD HINGE, WING SIDE LOWER MOUNT OTBD HOLE BORE CORROSION. HINGE REWORKED AND FOUND EXCEEDED LIMIT IAW CMM 57-44-09. EXISTING HOLE, DIA: 0.582" FINAL HOLE, DIA: 0.598" MAXIMUM ALLOWABLE DIA: 0.584". REPAIR BUSHING FABRICATED AND INSTALLED IAW EA 1-5750-T0325889, PT1 STEP 1A, WINGS-FLT SURFACES-EO 1-5750-7-5002, LT WING-OTBD FLAP, OTBD HINGE ASSY WING SIDE CORROSION REPAIR. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100.