What was found
LT WING INBD FLAP OTBD AFT HINGE, FLAP SIDE, PIVOT INBD HOLE BORE CORROSION. CORROSION FOUND EXCEEDED LIMIT IAW CMM 57-52-03. EXISTING HOLE DIA 1.251", FINAL HOLE DIA 1.283", MAXIMUM ALLOWABLE DIA 1.220". REPAIR BUSHING FABRICATED IAW EA 1-5750-71784E, PT5, STEP 4B AND INSTALLED IAW STEP 4E. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100. REF TO WRI 57509184 FOR WORK DETAILS.