What was found
LEFT WING INBD FLAP, OTBD AFT HINGE, FLAP SIDE, PIVOT OTBD HOLE BORE CORROSION. CORROSION FOUND EXCEEDED LIMIT IAW CMM 57-52-03. EXISTING HOLE DIA 1.251", FINAL HOLE DIA 1.375", MAXIMUM ALLOWABLE DIA 1.220". REPAIR BUSHING FABRICATED IAW EA 1-5750-71784E, PT5, STEP 4A AND INSTALLED IAW STEP 4D. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100. REF TO WRI: 57509184 FOR WORK DETAILS.