What was found
RIGHT WING INBD FLAP, OTBD AFT HINGE, FLAP SIDE, PIVOT INBD HOLE BORE CORROSION. CORROSION FOUND EXCEEDED LIMIT IAW CMM 57-52-03. EXISTING HOLE DIA 1.253", FINAL HOLE DIA 1.283", MAXIMUM ALLOWABLE DIA 1.220". REPAIR BUSHING FABRICATED IAW EA 1-5750-71783, C PART, 5 STEP 1A AND INSTALLED IAW STEP 1C AND 2. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100. REF TO WRI: 57509183 FOR WORK DETAILS.