What was found
02 EA, 10, NR 11, FASTENER HOLES FOUND CRACK INDICATION DURING OPEN-HOLE HFEC INSPECTION AT LT WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STA XORS =683.4 AND STA XORS =713.6. CARRIED OUT BUSHING REPAIR IAW SRM 57-20-02-2R, FIG 201 REPAIR 5. THE INITIAL INSPECTION NEEDED TO BE CARRIED OUT AT 2000 FLT CYCLES. REPETITIVE INSPECTION WILL BE CARRIED OUT AT EVERY 2000 FLT CYCLES IAW SRM 57-20-02-2R, TABLE 201, FIG 202 REPAIR 5. THE REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100.