What was found
12 EA, NR 7, 8, 9, 10, 11, 12, 13, 14, 28, 32, 33, 34, FASTENER HOLES FOUND CRACK INDICATION DURING OPEN-HOLE HFEC INSPECTION AT RT WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STA XORS =683.4 AND STA XORS =713.6. CARRIED OUT BUSHING REPAIR IAW SRM 57-20-02-2R, FIG 201 REPAIR 5. THE INITIAL INSPECTION TO BE CARRIED OUT AT 2000 FLT CYCLES, REPETITIVE INSPECTION WILL BE CARRIED OUT AT EVERY 2000 FLT CYCLES IAW SRM 57-20-02-2R, TABLE 201, FIG 202, REPAIR 5. THE REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.