What was found
FUSELAGE INTERNAL STRUCTURE AT FRAME 46, STR 24-STR 28LT FRAME FOOT INBD ROW UPR NR 1, FASTENER HOLE FOUND CRACK SIGNAL. REPAIRED THE CRACKED HOLE OF FUSELAGE INTERNAL STRUCTURE AT FRAME 46 STR 24-28 LT FRAME FOOT INBD ROW UPPER NR 1 FASTENER IAW EA 6-5315-T0326077 P1. FUSELAGE, FRAME, FOOT-CRACKS, FRAME FEET ATTACHMENT HOLES AT RT SIDE FRAME 41-43 AND LT SIDE FRAME 46. THIS REPAIR CATEGORY IS: C. REPAIR LIFE LIMITATION IS 6 MONTHS. MAJOR REPAIR IAW GMM 6-2-100.