What was found
FUSELAGE INTERNAL STRUCTURE AT FRAME 46, STR 24-28LT FRAME FOOT INBD ROW UPR NR 2 FASTENER HOLE FOUND CRACK SIGNAL. REPAIRED THE CRACKED HOLE OF FUSELAGE INTERNAL STRUCTURE AT FRAME 46, STR 24-28 LT FRAME FOOT INBD ROW UPPER NR 2 FASTENER IAW EA 6-5315-T0326077, P1. FUSELAGE, FRAME, FOOT CRACKS, FRAME FEET ATTACHMENT HOLES AT RT SIDE FR 41-43 AND LT SIDE FR46. THIS REPAIR CATEGORY IS: C. REPAIR LIFE LIMITATION IS 6 MONTHS. MAJOR REPAIR IAW GMM 6-2-100.