What was found
FUSELAGE INTERNAL STRUCTURE AT FRAME 43, STR 24-28 RT FRAME FOOT INBD ROW LWR NR 2 FASTENER HOLE FOUND CRACKED SIGNAL. REPAIRED THE CRACKED HOLE OF FUSELAGE INTERNAL STRUCTURE AT FRAME 43, STR 24-28, RT FRAME FOOT INBD ROW LOWER NR 2 FASTENER IAW EA 6-5315-T0326077 P1. FUSELAGE, FRAME, FOOT-CRACKS, FRAME FT ATTACHMENT HOLES AT RT SIDE FRAME 41-43 AND LT SIDE FRAME 46. THIS REPAIR CATEGORY IS: C. REPAIR LIFE LIMITATION IS 6 MONTHS. MAJOR REPAIR IAW GMM 6-2-100.