What was found
AFT PIT STA 1520, FRAME SPLICE S24R GOUGED. R & R SPLICE FRAME AT STA 1520, STR 24R, IAW-SRM-51-40-02-0G AND DWG 146N1017, THIS IS A CAT A REPAIR. REMOVED GOUGES IAW-SRM-51-10-02, ORIGINAL MATERIAL .071, REMAINING .041, OUT OF LIMITS IAW SRM-53-00-07-1A, FIG 101, DET II.