What was found
LEFT WING OTBD FLAP, OTBD FWD HINGE, WING SIDE, BARREL NUT UPPER HOLE BORE CORRODED. REWORKED AND FOUND EXCEEDED LIMIT IAW CMM 57-44-09. EXISTING HOLE: DIA 0.420", FINAL HOLE: DIA 0.423", MAXIMUM ALLOWABLE HOLE: DIA 0.391". REPAIR BUSHING FABRICATED AND INSTALLED IAW EA: 1-5750-T0326401, PART 1, STEP 1D. TITLE: WINGS-FLIGHT SURFACES, EO 1-5750-7-5002, LT WINGS, OTBD FLAP, OTBD HINGE ASSY, WING SIDE, CORROSION REPAIR. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100. REFER TO WRI: 57504779 FOR WORK DETAILS.