What was found
LEFT HAND WING INBOARD FLAP (FLAP SIDE) OUTBOARD AFT HINGE ACTUATOR OUTBOARD HOLE BORE CORRODED. REWORKED AND FOUND EXCEED LIMIT IAW CMM 57-52-03. EXISTING HOLE DIA: 1.219", FINAL HOLE DIA: 1.235" MAXIMUM ALLOWABLE HOLE DIA: 1.220". OVERSIZE BUSHING FABRICATED BY MACHINING IAW EA NR 1-5750-127720 B, PART 5, STEP 1B AND INSTALLED IAW EA 1-5750-127720 B, PART 5, STEP 1E. TITLE: WINGS, LT WING INBD FLAP OTBD HINGE, FLAP SIDE, PIVOT BORE-REPAIR. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100. REFER TO WRI: 57504773 FOR WORK DETAILS.