What was found
LT WING OTBD FLAP VANE FITTING D, BUSHING HOLE, CORRODED. BUSHING HOLE REWORKED AND FOUND EXCEED LIMIT AS PER SRM 57-50-02-2R FIGURE 201. EXISTING HOLE SIZE 0.876" X 0.580", FINAL HOLE SIZE: 0.953" X 0.660", MAXIMUM ALLOWABLE LIMIT: 0.940" X 0.670". OVERSIZE BUSHING FABRICATED AND INSTALLED PER EA 1-5750-T0326517 PART 1 STEP 2D. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100. REFER TO WRI: 57504768 FOR WORK DETAILS.