What was found
PASSING 11,000 FT ON DESCENT, RECEIVED A MOMENTARY FIRE INDICATION ON NR 3 ENGINE LASTED 2 SECONDS AND WENT AWAY. NO OTHER INDICATIONS LEFT ENGINE AT IDLE AND LANDED WITHOUT SHUTTING IT DOWN. PERFORMED FDCU-3 FAULT REVIEW, LOOP B FAULTED, UPPER RIGHT FIRE DETECTOR ASSY A AND LOOP A FAULTED. RETURNED TO SERVICE.