What was found
L-1 DOOR UPPER LINING SLIDING CLOSEOUT PANEL SPRING BROKEN AND PANEL DAMAGED. NO RESTRICTION, IAW 25-23-23-2 L1 DOOR UPPER LINING SLIDING CLOSEOUT PANEL SPRING BROKEN AND PANEL DAMAGED. REMOVED L1 DOOR SLIDING CEILING AND EXIT LIGHT PANEL ASSY IAW MM 25-23-23-2, PARA 2D. TERMINATED WIRES AT LT FORWARD DOOR EXIT SIGN, L2-721, IAW SWPM, AND WDM 33-52-01. TESTS NORMAL IAW AMM 33-52-01-5. TERMINATING ACTION ACCOMPLISHED FOR 25-23-23-2 AT 66,063:27 HR, 15,552 CYCLES, L1 DOOR UPPER LINING SLIDING CLOSEOUT PANEL. INSTALLED NEW SPRING, OPS CHECKED GOOD IAW MM 25-23-23-4.